H2S (Hydrogen Sulfide): 0 to 10 0 to 1000 ppmv 0 to 5000 ppmv 0 to 5% volume
Measured Variables
Concentration Cell Pressure Cell Temperature
Ambient Temperature range
-20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F)
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
Analyzer Wetted materials
316L stainless steel FKM O-Rings Glass
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 60W max (with 2 solenoids) - electronics enclosure 120 or 240 VAC, 50 to 60 Hz - standard; 100W or 200W max for heated systems - sample cabinet
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request
Housing materials
Electronics: Copper-free Aluminum Sample System Enclosure: 304 or 316 stainless steel
Hazardous area approvals
ATEX Zone 2
Degree of protection
IP66
Product safety
CE
Measuring principle
TDLAS
Channels
1
Analyte and Measurement ranges
H2O (Moisture): 0 to 10 ppmv 0 to 100 ppmv 0 to 50 ppmv 0 to 5000 ppmv
Measured Variables
Concentration Moisture Dew Point Cell Pressure Cell Temperature
Ambient Temperature range
-20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F)
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
Analyzer Wetted materials
316L stainless steel FKM O-Rings Glass
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 60W max (with 2 solenoids) - electronics enclosure 120 or 240 VAC, 50 to 60 Hz - standard; 100W or 200W max for heated systems - sample cabinet
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request
Housing materials
Electronics: Copper-free Aluminum Sample System Enclosure: 304 or 316 stainless steel
Hazardous area approvals
ATEX Zone 2
Degree of protection
IP66
Product safety
CE
Measuring principle
TDLAS
Channels
1
Analyte and Measurement ranges
CO2 (Carbon Dioxide): 0 to 10 ppmv 0 to 1000 ppmv 0 to 5000 ppmv 0 to 5% volume 0 to 10% volume 0 to 20% volume
Measured Variables
Concentration Cell Pressure Cell Temperature
Ambient Temperature range
-20 to 50°C (-4 to 122°F) Optional: -10 to 60°C (14 to 140°F)
Operating Pressure range
Inlet Pressure: 140 to 350 kPa (20 to 50 psig) Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
Analyzer Wetted materials
316L stainless steel FKM O-Rings Glass
Power supply
120 or 240 VAC ± 10 %, 50 to 60 Hz; 60W max (with 2 solenoids) - electronics enclosure 120 or 240 VAC, 50 to 60 Hz - standard; 100W or 200W max for heated systems - sample cabinet
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load (measurement value) Analog Input: One 4-20mA Isolated, 1200 ohms at 24 VDC max load (process pressure) Serial: RS232C and Ethernet Protocol: Modbus Gould RTU or Daniel RTU or ASCII Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active Digital Inputs: 2, Flow Alarm, Validation Request
Housing materials
Electronics: Copper-free Aluminum Sample System Enclosure: 304 or 316 stainless steel