FLOWSIC600-XT is available in variants with 4, 4+1, 4+4, and 8 measurement paths. In addition to the OIML R 137 Class 1.0 requirements, FLOWSIC600-XT meets the requirements of Class 0.5 and AGA9 in their entirety. FLOWSIC600-XT contains i-diagnostics™ – an intelligent application diagnostics function – and PowerIn Technology™ for continuous measurement operation for up to three weeks in the event of a mains voltage failure. For the very best possible measurement accuracy and long-term stability.
Custody transfer measurement of natural gas
Custody transfer measurement of natural gas with up to 30% H2
Transport and storage of gas
Onshore and offshore applications
Device properties:
Automatic adjustment of pressure and temperature influences
Available for all operating conditions
PowerIn Technology™ for reliable backup operation
Intelligent application diagnostics with i-diagnostics™
Measuring capability up to 30% hydrogen in natural gas
Benefits
Low measurement uncertainty in every application
Excellent measurement data reliability and availability
The right ultrasonic gas flow measuring device for every application – without compromise
Simple device integration – even in compact systems
Quick and easy commissioning and checks
Economical quantification of the H2 content in natural gas
Schluchseewerk AG wanted to record and optimize the efficiency of its turbines at the pumped storage plant in Wehr. Endress+Hauser offers the optimum solution with its ultrasonic clamp-on flowmeter.
GPsol, together with Endress+Hauser, developed a system that individually measures each component of extraction wells and provides as much information as possible about the current flow.
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Repeatability
≤ 0.05 % of the measured value (typical)
Accuracy
4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated
4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench.
4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
Medium temperature range
–46 °C ... +180 °C / -51 °F ... +356 °F On request:–194 °C ... +280 °C / –381 °F ... +536 °F
Operating pressure range
0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
Nominal pipe size
3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request
Metrological approvals and certificates
OIML R 137-1&2:2012 (class 0.5) OIML D 11:2013 ISO 17089-1 AGA-Report Nr. 9 MID: 2014/32/EU PED: 2014/68/EU ASME: B16.5, B16.47 A/B ATEX: 2014/34/EU EMC: 2014/30/EU GOST 8.611-2013 GOST 8.733-2011 CPA: JJG1030-2007 PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017
Hazardous area approvals
IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb Ex ia op is IIA/IIC T4 Ga
ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb II 1G Ex ia op is IIA/IIC T4 Ga NEC/CEC (US/CA) Explosion-proof / non-incendive: CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb Intrinsically safe: CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
Digital Outputs
4 outputs: 2 x status, 2 x pulse: ≤ 30 V, 50 mA Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable)
Oil and gas – solutions for the oil and gas industry
Industry Solution (SO)
English version - 01/2025
New version available in English
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most rigorous operating conditions.
Broad range of solutions for gas-fired power plants
Industry Solution (SO)
English version - 01/2025
New version available in English
With our broad range of solutions Endress+Hauser has proven applicability in the entire power generation process, from gas flow to combustion efficiency to emissions monitoring.