Liquiphant FTL51H - Vibronic

Vibronic
Point level detection
Liquiphant FTL51H

Point level switch with extension tube for liquids especially in the food and life sciences industry

FTL51H
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Premium device for point level detection
    in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Pipe extension up to 3 m (9,85 ft).
    Modular & completely welded housing concept,
    Wide range of certificates.

  • Specialities

    Plug and play functionalities,
    Surface finish: mechanical or electro-polished,
    Density/Concentration measurement,
    SIL 2/3 according to IEC 61508

  • Supply / Communication

    PROFIBUS PA,
    19 ..253V AC,
    10...55V DC-PNP,
    19...253V AC or 19...55V DC with relay DPDT,
    8/16mA,
    NAMUR,
    PFM

  • Ambient temperature

    -50 °C...+70 °C
    (-58 °F...+158 °F)

  • Process temperature

    -50 °C...+150 °C
    (-58 °F...+302 °F)

  • Process pressure / max. overpressure limit

    Vacuum...64 bar
    (Vacuum...928 psi)

  • Min. density of medium

    0.5g/cm³
    (0.4g/cm³ optional)

  • Main wetted parts

    316L

  • Process connection

    Threads (for weld-in adapter):
    G3/4A, G1A,
    Flange:
    DN25...DN100,
    ASME 1"...4",
    JIS 25A...100A

  • Process connection hygienic

    Tri-Clamp,
    DIN 11851, DIN11864-1
    Ingold,
    Flush mount,
    DRD,
    SMS1145,
    Varivent (Varinline)

  • Sensor length

    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118")

  • Communication

    PROFIBUS PA

  • Certificates / Approvals

    ATEX, IEC Ex, FM, CSA C/US, TIIS,
    INMETRO Ex, NEPSI Ex

  • Safety approvals

    Overfill protection WHG,
    SIL 2/ SIL 3

  • Design approvals

    Inspection certificate 3.1, EN10204,
    CoC ASME BPE,
    Conformity to cGMP,
    EU Food Contact Material (EC) 1935/2004,
    US Food Contact Material FDA CFR 21,
    CN Food Contact Material GB 4806,
    Declaration of Conformity ASME B31.3,
    AD2000,
    CRN approval

  • Hygienic approvals

    3-A,
    EHEDG,
    CoC-ASME BPE

  • Marine approval

    GL/ ABS/ DNV

  • Options

    Customized settings (Density)

  • Components

    FTL325P/FTL375P Interface PFM
    FTL325N/FTL375N Interface NAMUR

  • Successor

    FTL63

  • Measuring principle

    Vibration Density

  • Characteristic / Application

    Premium device for density measurement in hygienic/aseptic applications.
    Focus Food & Beverage and Life Sciences.
    Sensor with pipe extension up to 3 m (9,85 ft).
    Modular housing or completely welded compact housing.
    Wide range of certificates.

  • Supply / Communication

    via density controller FML621

  • Ambient temperature

    -40 °C...70 °C (-40...158 °F)

  • Process temperature

    0...80 °C (32…176 °F)

  • Process pressure

    0...25 bar (0…362 psi)

  • Wetted parts

    316L

  • Hygienic

    3A
    EHEDG

  • Sensor length

    Short tube (Liquiphant II)
    148mm…3000mm (6,00…118")

  • Output

    Pulse

  • Certificates / Approvals

    ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI

  • Specialities

    Density/Concentration measurement in combination
    with density controller FML621,
    Surface finish: mechanical polished (up to 0.3 µm)

  • Components

    Density Computer FML621