©Endress+Hauser
Specs at a glance
Input
Foundation Fieldbus protocol PROFIBUS PA protocol
Display
High contrast backlit LCD with bargraph TAG/unit
Field of application
The 8 channel indicator shows measured and calculated values and status information of the fieldbus users in a FOUNDATION Fieldbus™ or PROFIBUS® PA network. In the listener mode the device listens to the set fieldbus addresses and indicates their values. In addition, for FOUNDATION Fieldbus™ values available on the bus can be indicated via function block interconnection. A plain text field allows the display of the engineering unit or of the TAG. A bar graph is available for trend visualization.
Fieldbus indicator with 8 input channels and FOUNDATION Fieldbus™ or PROFIBUS® PA protocol for displaying process values and calculated values.
Benefits
Simple and standardized communication via fieldbus protocol
Listener mode for up to 8 input channels or digital status
Brilliant, backlit LC display with bar graph, diagnostic symbols and clear text field
No external power supply required
International approvals
Fundamental selection
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Predecessor
PROFIBUS-PA indicator RID261
Measuring principle
8 channel field indicator for fieldbuses
Function
Display values Advanced diagnostic
Display
High contrast backlit LCD with bargraph TAG/unit
Input
Foundation Fieldbus protocol PROFIBUS PA protocol
Software functions
Listener Mode On Foundation Fieldbus also function block connection: Display transducer block Advanced diagnostic block 2 x input selector Arithmetic block Integrator block PID block
Certificates
ATEX II1G Ex ia IIC T6 ATEX II3G Ex ic IIC T6 ATEX II2G Ex db IIC T6 Gb ATEX II2D Ex tb IIIC Db ATEX II3G Ex nA IIC T6 ATEX II1G Ex ia IIC T4/T5/T6, II2D CSA General Purpose CSA IS, NI I / 1+2/A-D CSA XP,NI,DIP I,II,III/1+2/A-G CSA XP,NI,DIP IS, NI I, II, III/1+2/A-G FM IS,NI I / 1+2/A-D FM XP,NI,DIP I,II,III/1+2/A-G FM XP,NI, DIP IS, NI I, II, III/1+2/A-G IECEx Ex ia IIC T6 Ga IECEx Ex db IIC T6 Gb IECEx Ex tb IIIC Db
Most downloaded
TI RID14
English version - 02/2023
8-channel field indicator
with FOUNDATION Fieldbus™ or PROFIBUS® PA protocol
EN
DE ES FR IT JA PT RU ZH
27/02/2023
13/09/2016
29/09/2015
24/10/2013
26/11/2009
Language:
English
Version:
27/02/2023
File size:
2.3 MB
File name:
TI00145REN_1623-00.pdf
BA RID14
English version - 01/2023
Fieldbus indicator
with FOUNDATION Fieldbus™ protocol
EN
DE ES FR IT JA PT RU ZH
31/01/2023
13/09/2016
29/04/2015
30/06/2014
24/02/2010
Language:
English
Version:
31/01/2023
File size:
4.3 MB
File name:
BA00282REN_1623-00.pdf
57 documents
8-channel field indicator with FOUNDATION Fieldbus™ or PROFIBUS® PA protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
27/02/2023
13/09/2016
29/09/2015
24/10/2013
26/11/2009
Language:
English
Version:
27/02/2023
File size:
2.3 MB
File name:
TI00145REN_1623-00.pdf
Fieldbus indicator with FOUNDATION Fieldbus™ protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
31/01/2023
13/09/2016
29/04/2015
30/06/2014
24/02/2010
Language:
English
Version:
31/01/2023
File size:
4.3 MB
File name:
BA00282REN_1623-00.pdf
Fieldbus indicator with PROFIBUS® PA protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
31/01/2023
13/09/2016
29/04/2015
22/10/2013
Language:
English
Version:
31/01/2023
File size:
4.2 MB
File name:
BA01267KEN_0423-00.pdf
8-channel field indicator with FOUNDATION Fieldbus™
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
31/01/2023
28/07/2022
08/09/2016
23/06/2014
01/12/2009
Language:
English
Version:
31/01/2023
File size:
3.1 MB
File name:
KA00281REN_1623-00.pdf
8-channel field indicator with PROFIBUS® PA protocol
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
31/01/2023
03/08/2022
08/09/2016
14/10/2013
Language:
English
Version:
31/01/2023
File size:
3.2 MB
File name:
KA01156KEN_0423-00.pdf
FOUNDATION Fieldbus™/PROFIBUS PA® FM: Control Drawing IS, NI, DIP 120800111
Language:
English
Version:
06/07/2009
File size:
114.1 KB
File name:
120800111.pdf
FOUNDATION Fieldbus™/PROFIBUS PA® CSA: Control Drawing XP, NI, DIP 120800114
Language:
English
Version:
06/07/2009
File size:
118.5 KB
File name:
120800114.pdf
FOUNDATION Fieldbus™/PROFIBUS PA® FM: Control Drawing XP, NI, DIP 120800113
Language:
English
Version:
06/07/2009
File size:
121.2 KB
File name:
120800113.pdf
PROFIBUS® PA, FOUNDATION Fieldbus™ ATEX: II 3G Ex ic IIC T6…T4 Gc Safety instructions for electrical apparatus in explosion-hazardous areas
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
27/04/2022
27/06/2016
22/05/2015
Language:
English
Version:
27/04/2022
File size:
383.1 KB
File name:
XA01157KEN_0322-00.pdf
ATEX: II1G Ex ia IIC T6...T4Ga IECEx: Ex ia IIC T6...T4 Ga Safety instructions for electrical apparatus in explosion-hazardous areas
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Italian Lithuanian Latvian Dutch Polish Portuguese Romanian Slovak Slovenian Swedish
28/03/2022
08/09/2015
09/10/2013
15/06/2010
Language:
English
Version:
28/03/2022
File size:
435.9 KB
File name:
XA00096REN_1622-00.pdf
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Display fitt. kit field housing
Drawing number
Order code
11
71310423
O-Ring 88x3 HNBR 70o Shore PTFE
Drawing number
Order code
7
71502617
O-Ring 18.77x1.78 HNBR 70o Shore PTFE
Cover latch spares kit field housing
Drawing number
Order code
8
51004948
Blind plug M20x1.5 EEx-d+O-ring Alu
Drawing number
Order code
9
71525620
Blind plug M20x1.5 Ex-d+O-ring V4A
Drawing number
Order code
9
71525622
Blind plug G1/2" Ex-d+O-ring Alu
Drawing number
Order code
9
71525621
Blind plug G1/2" Ex-d+O-ring V4A
Drawing number
Order code
9
71525623
Blanks (blind) NPT1/2, 3.1655.53
Drawing number
Order code
9
51004490
Blanks (blind) NPT1/2 V4A
Drawing number
Order code
9
51006888
Drawing number
Order code
1
RIA141G-
Accessories System Products
Drawing number
Order code
10
RK01-
Plug for Thermometer + Transmitter
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all