"Product Phased Out".
Level, radar, guided.
Hygienic.
Application: liquids.
Factory precalibrated.
Incl. Setup-/diagnostic software.
:: Reliable measuring:
in case of moved surface + foam,
for changing medias.
-
Successor
-
For the highest hygiene requirements in the food and life sciences industry
-
Simple products
-
Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
-
Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
High-end products
-
Highly functional and convenient
Technical excellence
Simplicity
-
Specialized products
-
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections |
Technical excellence |
Simplicity |
Fundamental selection
Meet your basic measurement needs
|
Technical excellence
|
Simplicity
|
Lean selection
Handle your core processes easily
|
Technical excellence
|
Simplicity
|
Extended selection
Optimize your processes with innovative technologies
|
Technical excellence
|
Simplicity
|
Xpert selection
Master your most challenging applications
|
Technical excellence
|
Simplicity
|
-
Characteristic / Application
Rod probe:
not affected by spray ball operation
Probes electro-polished or mechanically polished
-
Specialities
Pharma Certificate of Compliance
-
Supply / Communication
2-wire (HART / PROFIBUS PA / FOUNDATION Fieldbus)
-
Accuracy
Rod probe: +/-3 mm (0.13")
-
Ambient temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
-
Process temperature
-20 °C ... 150 °C
(-4 °F ... 302 °F)
-
Process pressure / max. overpressure limit
-
Main wetted parts
316L/1.4435
PEEK (USP Cl. VI)
EPDM / KALREZ (USP Cl. VI)
-
Process connection
Flange: ASME B16.5 1 1/2", 2"
-
Process connection hygienic
Tri-Clamp ISO2852
DIN11851
SMS
DIN11864
NEUMO Biocontrol
-
-
Max. measurement distance
Rod probe :
4 m (178") Min. DK > 1.6
-
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
-
-
-
Most downloaded
-
Levelflex M FMP43
Technical Information
English version - 10/2012
|
Guided Level-Radar
Continuous Level Transmitter for continuous level measurement
in liquids in hygienic applications.
|
EN
|
|
More
|
15/10/2012
|
|
|
|
13/09/2012
|
|
|
|
22/12/2010
|
|
|
|
14/04/2009
|
|
|
|
01/06/2007
|
|
|
|
Language:
|
English
|
Version:
|
15/10/2012
|
File size:
|
3.5 MB
|
File name:
|
TI00424FEN_1512.pdf
|
-
Electronic module (Interface measurement)
Installation instruction
English version - 04/2012
|
Levelflex M, FMP40, FMP41C, FMP43, FMP45
Language:
|
English
|
Version:
|
11/04/2012
|
File size:
|
394.4 KB
|
File name:
|
EA0001FA2_0508.pdf
|
83 documents
-
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
|
EN
|
|
Select other language
|
25/03/2024
|
|
|
|
15/09/2023
|
|
|
|
28/10/2021
|
|
|
|
30/07/2021
|
|
|
|
19/06/2020
|
|
|
|
Language:
|
English
|
Version:
|
25/03/2024
|
File size:
|
1.1 MB
|
File name:
|
TI00426FEN_2524.pdf
|
-
Levelflex M FMP43
Technical Information
Guided Level-Radar
Continuous Level Transmitter for continuous level measurement
in liquids in hygienic applications.
|
EN
|
|
Select other language
|
15/10/2012
|
|
|
|
13/09/2012
|
|
|
|
22/12/2010
|
|
|
|
14/04/2009
|
|
|
|
01/06/2007
|
|
|
|
Language:
|
English
|
Version:
|
15/10/2012
|
File size:
|
3.5 MB
|
File name:
|
TI00424FEN_1512.pdf
|
-
|
EN
|
|
Select other language
|
24/04/2009
|
|
|
|
10/08/2007
|
|
|
|
Language:
|
English
|
Version:
|
24/04/2009
|
File size:
|
802.6 KB
|
File name:
|
BA360FEN_0409.pdf
|
-
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
01/07/2007
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
189.7 KB
|
File name:
|
BA00361FA6_1310.pdf
|
-
|
EN
|
|
Select other language
|
10/08/2007
|
|
|
|
Language:
|
English
|
Version:
|
10/08/2007
|
File size:
|
181.9 KB
|
File name:
|
BA362FA6_0807.pdf
|
-
Levelflex M FMP43
HART
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
14/04/2009
|
|
|
|
01/07/2007
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
5 MB
|
File name:
|
BA00357FEN_1310.pdf
|
-
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PA, FF
Description of Instrument Functions
Smart Transmitter for continuous
level measurement in liquids
|
EN
|
|
Select other language
|
01/07/2007
|
|
|
|
07/06/2006
|
|
|
|
25/01/2006
|
|
|
|
12/07/2004
|
|
|
|
23/02/2004
|
|
|
|
Language:
|
English
|
Version:
|
01/07/2007
|
File size:
|
1.5 MB
|
File name:
|
BA245FEN_0707.pdf
|
-
Levelflex M FMP43
PROFIBUS PA
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
14/04/2009
|
|
|
|
01/07/2007
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
5.8 MB
|
File name:
|
BA00358FEN_1310.pdf
|
-
Levelflex M FMP43
FOUNDATION Fieldbus
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for continuous level measurement in liquids
in hygienic applications.
|
EN
|
|
Select other language
|
11/11/2010
|
|
|
|
28/08/2009
|
|
|
|
14/04/2009
|
|
|
|
01/07/2007
|
|
|
|
Language:
|
English
|
Version:
|
11/11/2010
|
File size:
|
6 MB
|
File name:
|
BA00359FEN_1310.pdf
|
-
FMP4x - Exchange of housing F12
FMP4x - Exchange of housing F12
|
EN
|
|
Select other language
|
16/04/2021
|
|
|
|
Language:
|
English
|
Version:
|
16/04/2021
|
File size:
|
375.2 KB
|
File name:
|
KA00576F00_A2.pdf
|
Search spare parts by number in drawing
52 spare parts & accessories
52 spare parts
52 accessories
-
-
Set of screws housing F12/T12/F23
Drawing number
Order code
12
535720-9020
-
Cover F12/T12 Alu, coated, gasket
Drawing number
Order code
20
517391-0011
-
Cover F12/T12 Alu, window, gasket
Drawing number
Order code
20
52005936
-
Cover T3/T12 Alu, coated, gasket
Drawing number
Order code
25
518710-0020
-
Cover terminal compartment F12/F23
Drawing number
Order code
11
52006026
-
Cover terminal compartment F12/F23,FHX40
Drawing number
Order code
11
52019062
-
Terminal module 4-pole, HART, 2-wire
Drawing number
Order code
35
52006197
-
Terminal module 4-pole, PA, FF
Drawing number
Order code
35
52012156
-
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Drawing number
Order code
35
52013302
-
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
Drawing number
Order code
35
52013303
-
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
Drawing number
Order code
35
52018949
-
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
Drawing number
Order code
35
52018950
-
Drawing number
Order code
11
52005643
-
Power supply 10.5-32VDC (housing F12)
Drawing number
Order code
35
52013304
-
Power supply 90-250VAC (F12), Ex only
Drawing number
Order code
35
52013305
-
Power supply CSA, 10.5-32VDC (housg F12)
Drawing number
Order code
35
52015585
-
Power supply CSA, 90-250VAC (housg F12)
Drawing number
Order code
35
52015586
-
Drawing number
Order code
40
52026443
-
Aseptic coupling DIN11864-1 A DN25 tube
Drawing number
Order code
52
71043425
-
Dairy fitting DIN11851 DN40 PN40
Drawing number
Order code
52
71043426
-
Dairy fitting DIN11851 DN50 PN40
Drawing number
Order code
52
71043427
-
Adapter NEUMO BioControl DN25 PN16
Drawing number
Order code
52
71043428
-
Tri-Clamp ISO2852 DN25-38 1..1-1/2"
Drawing number
Order code
52
71043429
-
Tri-Clamp ISO2852 DN40-51 2"
Drawing number
Order code
52
71043430
-
Tri-Clamp ISO2852 DN70-76.1 3"
Drawing number
Order code
52
71043438
-
Adapter SMS 2" PN25, 316L
Drawing number
Order code
52
71043439
-
Adapter SMS 1-1/2" PN25, 316L
Drawing number
Order code
52
71043440
-
Aseptic coupl.DIN11864-1 A DN25 tube,3.1
Drawing number
Order code
52
71043443
-
Dairy fitting DIN11851 DN40 PN40, 3.1
Drawing number
Order code
52
71043444
-
Dairy fitting DIN11851 DN50 PN40, 3.1
Drawing number
Order code
52
71043445
-
Adapter NEUMO BioControl DN25 PN16, 3.1
Drawing number
Order code
52
71043446
-
Tri-Clamp ISO2852 DN25-38 1..1-1/2", 3.1
Drawing number
Order code
52
71043447
-
Tri-Clamp ISO2852 DN40-51 2", 3.1
Drawing number
Order code
52
71043448
-
Tri-Clamp ISO2852 DN70-76.1 3", 3.1
Drawing number
Order code
52
71043449
-
Adapter SMS 2" PN25, 316L, 3.1
Drawing number
Order code
52
71043450
-
Adapter SMS 1-1/2" PN25, 316L, 3.1
Drawing number
Order code
52
71043451
-
Sealing kit FMP43,FMP53 Kalrez, 2 pieces
Drawing number
Order code
57
71043452
-
Sealing kit FMP43, FMP53 EPDM, 2 pieces
Drawing number
Order code
57
71043453
-
Adaption kit housing F12, 2-wire, FHX40
-
Adaption kit housing F12, 4-wire, FHX40
-
-
-
-
-
Protective cover for housing T12/F12, SS
-
Mounting bracket FHX40 1" / 2" pipe
-
-
Weld-in adapter M24 D65, 316L
-
Weld-in adapter M24 D65, 316L, 3.1
-
Protective cover FMP43/53
-
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .